<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Med Inform</journal-id><journal-id journal-id-type="publisher-id">medinform</journal-id><journal-id journal-id-type="index">7</journal-id><journal-title>JMIR Medical Informatics</journal-title><abbrev-journal-title>JMIR Med Inform</abbrev-journal-title><issn pub-type="epub">2291-9694</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v14i1e95500</article-id><article-id pub-id-type="doi">10.2196/95500</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Paper</subject></subj-group></article-categories><title-group><article-title>Development and Content Validation of a Self-Assessment Checklist for Electronic Medical Record Use Certification in Korea: Convergent Mixed Methods Study</article-title></title-group><contrib-group><contrib contrib-type="author" equal-contrib="yes"><name name-style="western"><surname>Chung</surname><given-names>Joohyun</given-names></name><degrees>RN, PhD</degrees><xref ref-type="aff" rid="aff1">1</xref><xref ref-type="fn" rid="equal-contrib1">*</xref></contrib><contrib contrib-type="author" equal-contrib="yes"><name name-style="western"><surname>Park</surname><given-names>Ye-Eun</given-names></name><degrees>BA</degrees><xref ref-type="aff" rid="aff2">2</xref><xref ref-type="fn" rid="equal-contrib1">*</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Kim</surname><given-names>Yoomi</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Lee</surname><given-names>Jae-Ho</given-names></name><degrees>MD, PhD</degrees><xref ref-type="aff" rid="aff2">2</xref><xref ref-type="aff" rid="aff4">4</xref></contrib><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>Lee</surname><given-names>Yura</given-names></name><degrees>MD, PhD</degrees><xref ref-type="aff" rid="aff2">2</xref></contrib></contrib-group><aff id="aff1"><institution>College of Nursing, University of Massachusetts Amherst</institution><addr-line>Amherst</addr-line><addr-line>MA</addr-line><country>United States</country></aff><aff id="aff2"><institution>Department of Information Medicine, University of Ulsan College of Medicine, Asan Medical Center</institution><addr-line>88 Olympic-ro 43-gil</addr-line><addr-line>Seoul</addr-line><country>Republic of Korea</country></aff><aff id="aff3"><institution>Electronic Medical Records System Certification Criteria Development Department, Korea Health Information Service</institution><addr-line>Seoul</addr-line><country>Republic of Korea</country></aff><aff id="aff4"><institution>Department of Emergency Medicine, University of Ulsan College of Medicine, Asan Medical Center</institution><addr-line>Seoul</addr-line><country>Republic of Korea</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Coristine</surname><given-names>Andrew</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Ren</surname><given-names>Anjie</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Jung</surname><given-names>Kwang Yul</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Yura Lee, MD, PhD, Department of Information Medicine, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gilSeoul, 05505, Republic of Korea, 82 2-3010-1498, 82 2-3010-2531; <email>haepary@naver.com</email></corresp><fn fn-type="equal" id="equal-contrib1"><label>*</label><p>these authors contributed equally</p></fn></author-notes><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>4</day><month>11</month><year>2026</year></pub-date><volume>14</volume><elocation-id>e95500</elocation-id><history><date date-type="received"><day>17</day><month>03</month><year>2026</year></date><date date-type="rev-recd"><day>16</day><month>09</month><year>2026</year></date><date date-type="accepted"><day>23</day><month>09</month><year>2026</year></date></history><copyright-statement>&#x00A9; Joohyun Chung, Ye-Eun Park, Yoomi Kim, Jae-Ho Lee, Yura Lee. Originally published in JMIR Medical Informatics (<ext-link ext-link-type="uri" xlink:href="https://medinform.jmir.org">https://medinform.jmir.org</ext-link>), 4.11.2026. </copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Informatics, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://medinform.jmir.org/">https://medinform.jmir.org/</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://medinform.jmir.org/2026/1/e95500"/><abstract><sec><title>Background</title><p>Electronic medical record (EMR) certification programs have traditionally focused on product-level requirements, such as interoperability, security, and core functionality. However, growing evidence suggests that many patient safety risks associated with EMRs arise after implementation and are closely related to system configuration, workflow integration, and real-world use. Despite the presence of a national EMR product certification system in Korea, a systematic evaluation of how certified systems are implemented and used in clinical practice is still lacking.</p></sec><sec><title>Objective</title><p>This study aimed to develop and validate a self-assessment checklist for EMR use certification, focused on patient safety-critical functions, and to evaluate its content validity and expert-assessed practical applicability across health care institutions of different sizes.</p></sec><sec sec-type="methods"><title>Methods</title><p>A convergent mixed methods design was used. A self-assessment checklist comprising 10 patient safety&#x2013;related EMR functions was developed by adapting the US Office of the National Coordinator for Health Information Technology self-assessment templates to the Korean EMR certification context. Content validity was quantitatively assessed using the Content Validity Index across 4 dimensions (relevance, usefulness, clarity, and importance) by a panel of 24 experts with experience in EMR implementation and certification. Qualitative feedback was collected through open-ended survey questions to examine feasibility, anticipated challenges, and differentiation between product and use certification across tertiary referral hospitals, general hospitals, and clinics.</p></sec><sec sec-type="results"><title>Results</title><p>The overall Scale-Level Content Validity Index was 0.921, indicating strong content validity for the proposed checklist. Although most items demonstrated high agreement, lower ratings were observed for certain functions, particularly in clinic-level settings, reflecting structural and resource-related constraints rather than limited recognition of patient safety priorities. Qualitative findings highlighted challenges related to staffing, system governance, and the feasibility of assembling multidisciplinary assessment teams in smaller institutions.</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>The self-assessment checklist demonstrated high content validity and was perceived as relevant for evaluating patient safety&#x2013;critical aspects of EMR use. However, expert-assessed feasibility varied across health care institution types, particularly in clinic-level settings. Further empirical testing is needed to assess the checklist&#x2019;s reliability, usability, and applicability in real-world certification processes.</p></sec></abstract><kwd-group><kwd>electronic medical record</kwd><kwd>certification</kwd><kwd>patient safety</kwd><kwd>clinical workflow</kwd><kwd>content validity</kwd><kwd>self-assessment</kwd><kwd>clinical decision support</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>The adoption of electronic medical record (EMR) systems has accelerated worldwide, highlighting the need for mechanisms to ensure the safety, quality, and interoperability of digital health infrastructures. International organizations such as the World Health Organization (WHO) emphasize the importance of robust digital health strategies, governance, trust, and reliable information exchange across health care settings [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref2">2</xref>]. Importantly, digital transformation in health care must be accompanied by safeguards that protect patients from technology-related errors and unintended consequences [<xref ref-type="bibr" rid="ref3">3</xref>-<xref ref-type="bibr" rid="ref5">5</xref>]. As EMRs become integral to clinical decision-making, medication management, communication, and care coordination, ensuring their safe use has emerged as a critical patient safety priority [<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref6">6</xref>].</p><p>Many countries have introduced EMR certification programs that primarily evaluate product-level requirements, including interoperability, privacy and security, and core functionality. In the United States, the Office of the National Coordinator for Health Information Technology (ONC) operates a national health IT certification program that defines technical and functional standards for certified health IT [<xref ref-type="bibr" rid="ref7">7</xref>]. However, technical conformance alone does not ensure the safe and effective use of EMR systems in clinical practice. Prior studies, sociotechnical frameworks, and recent reviews have emphasized that health IT&#x2013;related safety risks often emerge after implementation through system configuration, workflow integration, alert design, user interaction, and EMR usability problems [<xref ref-type="bibr" rid="ref8">8</xref>-<xref ref-type="bibr" rid="ref11">11</xref>]. Technology-induced errors may contribute to medication errors, delayed diagnoses, communication failures, documentation inaccuracies, and other patient safety events. Research has shown that these risks often arise from mismatches between EMR design and clinical workflows, inadequate governance processes, and unintended consequences of system customization rather than from software malfunctions alone [<xref ref-type="bibr" rid="ref12">12</xref>-<xref ref-type="bibr" rid="ref15">15</xref>]. Complementary frameworks such as the Healthcare Information and Management Systems Society&#x2019;s electronic medical record adoption model further illustrate the importance of evaluating how EMR systems are implemented and used within clinical organizations [<xref ref-type="bibr" rid="ref16">16</xref>].</p><p>Korea has established a national EMR product certification program and promotes the use of standard terminologies and interoperability guidelines [<xref ref-type="bibr" rid="ref17">17</xref>]. However, systematic approaches for assessing how certified EMR systems are configured, used, and governed in Korean clinical practice remain limited, despite broader evidence that postimplementation health IT risks are shaped by sociotechnical factors such as configuration, usability, workflow integration, and governance [<xref ref-type="bibr" rid="ref18">18</xref>-<xref ref-type="bibr" rid="ref20">20</xref>]. Korea has experienced early and rapid adoption of EMR systems, particularly in tertiary and general hospitals; however, this rapid diffusion has been accompanied by concerns about patient safety, system usability, interoperability, and workflow integration in Korean EMR environments [<xref ref-type="bibr" rid="ref21">21</xref>-<xref ref-type="bibr" rid="ref27">27</xref>]. Given that patient safety outcomes depend not only on the technical capabilities of EMR systems but also on how these systems are implemented and used in routine care, there is a growing need for mechanisms that can identify potential safety vulnerabilities before they contribute to adverse events. Such mechanisms may support health care organizations in strengthening safe EMR practices, promoting organizational learning, and reducing technology-related patient harm [<xref ref-type="bibr" rid="ref12">12</xref>,<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref28">28</xref>].</p><p>Taken together, international experience suggests the need for a complementary use certification framework that evaluates the appropriateness, clarity, and feasibility of EMR functions in real clinical settings [<xref ref-type="bibr" rid="ref29">29</xref>-<xref ref-type="bibr" rid="ref31">31</xref>]. A use-focused certification approach may provide an additional layer of patient safety assurance by evaluating whether safety-critical EMR functions are appropriately configured and supported by organizational governance, interoperable information exchange, workflow-aligned implementation practices, and adequate user training and support [<xref ref-type="bibr" rid="ref32">32</xref>,<xref ref-type="bibr" rid="ref33">33</xref>]. Such an approach recognizes that patient safety risks may emerge not only from technical deficiencies but also from interactions among system usability, information quality, workflow integration, clinician cognitive workload, and organizational factors that influence the safe and effective use of EMRs in routine care [<xref ref-type="bibr" rid="ref3">3</xref>,<xref ref-type="bibr" rid="ref4">4</xref>,<xref ref-type="bibr" rid="ref34">34</xref>]. To address this gap in the Korean context, this study aimed to develop a self-assessment checklist for EMR use certification based on Korea Health Information Service (KHIS)&#x2013;designated patient safety&#x2013;critical certification items. Specifically, the study aimed to evaluate the content validity of the checklist using expert ratings across relevance, usefulness, clarity, and importance and examine expert-perceived feasibility across tertiary referral hospitals, general hospitals, and clinics.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Study Design</title><p>This study used a convergent mixed methods design to develop and validate a self-assessment checklist for EMR use certification within the Korean context. Quantitative data were used to assess the content validity of selected certification items, whereas qualitative feedback was collected to examine clarity, applicability, and alignment with real-world clinical practice. In this study, &#x201C;EMR&#x201D; is used as the primary term to reflect the terminology of the Korean certification program; &#x201C;EHR&#x201D; (electronic health record) is retained only when referring to international frameworks or source materials that use the term &#x201C;EHR.&#x201D;</p></sec><sec id="s2-2"><title>Participants and Recruitment</title><p>A purposive sampling strategy was used to recruit experts with direct experience in EMR implementation, evaluation, or certification in Korea. Of the 31 individuals invited, 24 experts with a response rate of 77.4% participated. Participants were affiliated with professional organizations, including the Korean Medical Informatics Association, the Korean Hospital Information Association, the Korean Society for Patient Safety, and a national health IT usability and safety research group.</p><p>Eligibility criteria included substantial experience with EMR systems, certification processes, and professional roles such as health care IT specialists, clinicians (physicians, nurses, and pharmacists), policymakers, or representatives of relevant associations. Snowball sampling was also used to broaden disciplinary representation. The sample size was selected based on recommendations by Lynn, who suggested that 5 to 10 experts are adequate for content validity evaluation, and by Polit and Beck, who recommended a minimum item-level Content Validity Index (I-CVI) threshold of 0.78 when 6 or more experts are involved [<xref ref-type="bibr" rid="ref35">35</xref>,<xref ref-type="bibr" rid="ref36">36</xref>]. The experts independently rated each item across 4 dimensions using a 4-point scale. I-CVI and scale-level Content Validity Index (S-CVI/Ave) were subsequently calculated. All participants provided informed consent prior to participation.</p></sec><sec id="s2-3"><title>Development of the EMR Use Self-Assessment Checklist</title><p>The self-assessment checklist was developed based on 10 patient safety-critical functional items identified from the Korean EMR product certification standards established by KHIS. The KHIS EMR certification system is divided into 3 major categories (interoperability, safety and security, and functionality) and includes 28, 20, and 12 detailed certification items, respectively (<xref ref-type="fig" rid="figure1">Figure 1</xref>). Among these 60 certification items, 10 were designated by KHIS as patient safety-critical functional items with high relevance for field verification. These KHIS-designated items served as the basis for developing and validating the EMR use self-assessment checklist. Drug Allergy and Hypersensitivity (A009) and Safe Prescription of Medication Dosages (A020) were retained as separate KHIS-designated items because they represent distinct medication-safety functions within the Korean EMR certification framework. A009 focuses on recording and reviewing medication allergy and hypersensitivity information, whereas A020 focuses on safe medication dosage prescribing, including patient-specific dose calculation, linkage between calculated doses and prescription entry, and dosage-range review. The details of these 10 items are shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>Overview of the electronic medical record (EMR) certification framework in Korea, including the structure of product and use certification and core evaluation domains (interoperability, safety and security, and functionality). KHIS: Korea Health Information Service.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="medinform_v14i1e95500_fig01.png"/></fig><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Ten certification items for the &#x201C;certification of use&#x201D; process.</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Product certification code</td><td align="left" valign="bottom">Item</td><td align="left" valign="bottom">Definitions</td></tr></thead><tbody><tr><td align="left" valign="top">A003</td><td align="left" valign="top">PI<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup></td><td align="left" valign="top">Ensures the system accurately identifies patients using multiple identifiers (eg, name, ID number, and date of birth)</td></tr><tr><td align="left" valign="top">A009</td><td align="left" valign="top">DAH<sup><xref ref-type="table-fn" rid="table1fn2">b</xref></sup></td><td align="left" valign="top">The EMR<sup><xref ref-type="table-fn" rid="table1fn3">c</xref></sup> must allow recording and reviewing of a patient&#x2019;s allergies or hypersensitivities to medications</td></tr><tr><td align="left" valign="top">A017</td><td align="left" valign="top">DIA<sup><xref ref-type="table-fn" rid="table1fn4">d</xref></sup></td><td align="left" valign="top">Provides alerts for potential adverse reactions when a drug is ordered that may interact with other medications or allergies</td></tr><tr><td align="left" valign="top">A018</td><td align="left" valign="top">MEP<sup><xref ref-type="table-fn" rid="table1fn5">e</xref></sup></td><td align="left" valign="top">The system includes checks and balances (eg, autocomplete, dosage suggestions, and alerts) to reduce entry errors during medication ordering.</td></tr><tr><td align="left" valign="top">A019</td><td align="left" valign="top">IRAM<sup><xref ref-type="table-fn" rid="table1fn6">f</xref></sup></td><td align="left" valign="top">Prevents or alerts users when a medication is ordered via an incorrect or dangerous route (eg, oral vs intravenous)</td></tr><tr><td align="left" valign="top">A020</td><td align="left" valign="top">SPMD<sup><xref ref-type="table-fn" rid="table1fn7">g</xref></sup></td><td align="left" valign="top">Supports calculation and review of patient-specific medication dosages during prescribing to promote safe medication use</td></tr><tr><td align="left" valign="top">A021</td><td align="left" valign="top">BRMA<sup><xref ref-type="table-fn" rid="table1fn8">h</xref></sup></td><td align="left" valign="top">Supports scanning barcodes or RFID<sup><xref ref-type="table-fn" rid="table1fn9">i</xref></sup> tags on patient ID bands and medications during administration to verify correct patient, drug, and time</td></tr><tr><td align="left" valign="top">A022</td><td align="left" valign="top">MIP<sup><xref ref-type="table-fn" rid="table1fn10">j</xref></sup></td><td align="left" valign="top">Provides clinicians and/or patients with detailed drug information (eg, dosage, side effects, and contraindications)</td></tr><tr><td align="left" valign="top">A024</td><td align="left" valign="top">CTRN<sup><xref ref-type="table-fn" rid="table1fn11">k</xref></sup></td><td align="left" valign="top">Automatically alerts clinicians about life-threatening or time-sensitive test results (eg, abnormal laboratory values)</td></tr><tr><td align="left" valign="top">A025</td><td align="left" valign="top">APM<sup><xref ref-type="table-fn" rid="table1fn12">l</xref></sup></td><td align="left" valign="top">Tracks antibiotic prescribing patterns, includes alerts for inappropriate use, and may support antimicrobial stewardship</td></tr></tbody></table><table-wrap-foot><fn id="table1fn1"><p><sup>a</sup>PI: Patient Identification.</p></fn><fn id="table1fn2"><p><sup>b</sup>DAH: Drug Allergy and Hypersensitivity.</p></fn><fn id="table1fn3"><p><sup>c</sup>EMR: electronic medical record.</p></fn><fn id="table1fn4"><p><sup>d</sup>DIA: Drug Interaction and Allergy Alert.</p></fn><fn id="table1fn5"><p><sup>e</sup>MEP: Medication Entry Error Prevention.</p></fn><fn id="table1fn6"><p><sup>f</sup>IRAM: Inappropriate Route of Administration Management.</p></fn><fn id="table1fn7"><p><sup>g</sup>SPMD: Safe Prescription of Medication Dosages.</p></fn><fn id="table1fn8"><p><sup>h</sup>BRMA: Barcode or RFID Medication Administration.</p></fn><fn id="table1fn9"><p><sup>i</sup>RFID: radio frequency identification.</p></fn><fn id="table1fn10"><p><sup>j</sup>MIP: Medication Information Provision.</p></fn><fn id="table1fn11"><p><sup>k</sup>CTRN: Critical Test Result Notification.</p></fn><fn id="table1fn12"><p><sup>l</sup>APM: Antibiotic Prescription Management.</p></fn></table-wrap-foot></table-wrap><p>To enhance international alignment, the checklist was adapted from the US ONC self-assessment templates and modified to reflect Korean regulatory requirements, clinical workflows, and institutional contexts [<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref17">17</xref>,<xref ref-type="bibr" rid="ref29">29</xref>]. The adaptation process was conducted by 2 investigators and involved reviewing the ONC templates, mapping relevant elements to the Korean certification criteria, and revising wording and response fields for contextual relevance.</p><p>Disagreements regarding mapping or wording were resolved through research team discussion, and the revised checklist was reviewed by health care IT professionals for practical usability. The complete checklist, including item-specific purposes, assessment questions, implementation status options, improvement and management plan fields, and organizational responsibility checklists, is provided in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p></sec><sec id="s2-4"><title>Data Collection</title><p>Data were collected between December 2023 and March 2024 using a structured, web-based survey. Quantitative evaluation used the CVI framework [<xref ref-type="bibr" rid="ref35">35</xref>], with participants rating each of the 10 certification items on a 4-point Likert scale across 4 dimensions: relevance, usefulness, clarity, and importance. All 24 experts were invited to rate each certification item separately for 3 health care institution types; I-CVI calculations were based on the number of valid ratings for each item-dimension-institution&#x2013;type combination. Missing ratings were excluded only from the specific item-dimension-institution&#x2013;type calculation in which they occurred. The expert validation survey was distinct from the clinical self-assessment checklist developed for future institutional use. In the expert survey, the unit of CVI evaluation was the certification item/domain, not the individual subquestions or organizational responsibility questions embedded in the checklist. These embedded questions were included as operational components to guide future institutional self-assessment of implementation status, governance, accountability, and readiness.</p><p>To assess pragmatic feasibility, participants also evaluated 3 implementation-related domains, referred to in this study as practical features: ease of completion, target respondent suitability, and content adequacy. These practical features were rated using 4-point scales, with higher scores indicating more favorable evaluations: ease of completion (1=&#x201C;not easy&#x201D; to 4=&#x201C;very easy&#x201D;), target respondent suitability (1=&#x201C;insufficient&#x201D; to 4=&#x201C;fully sufficient&#x201D;), and content adequacy (1=&#x201C;negative&#x201D; to 4=&#x201C;positive&#x201D;). As part of the summary evaluation, for each health care institution type, experts were asked to estimate the minimum number of participants or professional roles required to complete the 10 self-assessment forms.</p><p>Qualitative data for this study consisted of free-text responses to open-ended questions included in the expert validation survey. These questions addressed anticipated implementation challenges, differentiation from product certification, and applicability across clinical settings. These responses were distinct from the &#x201C;improvement and management plan&#x201D; fields embedded in the clinical self-assessment checklist, which were intended for future institutional completion during actual self-assessment and were not analyzed in this study.</p></sec><sec id="s2-5"><title>Data Analysis</title><p>Data were analyzed using SAS version 9.4 (SAS Institute Inc). I-CVI values were calculated at the certification item/domain level as the proportion of experts rating an item as 3 or 4. An I-CVI value &#x2265;0.78 was considered acceptable [<xref ref-type="bibr" rid="ref36">36</xref>]. I-CVI values were computed separately for each domain (clarity, importance, relevance, and usefulness) and for each health care institution type (tertiary referral hospitals, general hospitals, and clinics). S-CVI/Ave was computed as the average of the I-CVI values to assess overall content validity.</p><p>To adjust for chance agreement among experts, modified &#x03BA; (&#x03BA;*) coefficients were calculated for each item-dimension-institution&#x2013;type combination. The probability of chance agreement was estimated based on the number of valid ratings and the observed level of agreement for each item-dimension-institution&#x2013;type combination. &#x03BA;* was computed as &#x03BA;*=(I-CVI&#x2212;Pc)/(1&#x2212;Pc), where I-CVI indicates the observed proportion of agreement among experts and Pc indicates the probability of chance agreement [<xref ref-type="bibr" rid="ref36">36</xref>-<xref ref-type="bibr" rid="ref38">38</xref>]. Interpretation of &#x03BA;* followed established criteria: &#x2265;0.90, excellent agreement; 0.80 to 0.89, good agreement; 0.70 to 0.79, acceptable agreement; &#x003C;0.70, poor agreement.</p><p>Descriptive statistics, including means and SDs, were calculated for practical feature ratings and summary evaluation items, including the estimated minimum number of participants or professional roles required to complete the self-assessment forms by health care institution type.</p><p>Qualitative responses from the open-ended survey questions were analyzed using qualitative content analysis with an inductive coding approach. Two investigators independently reviewed all responses, generated initial codes, and grouped similar codes into preliminary categories. Coding results were then compared to identify discrepancies in code assignment, category boundaries, and theme interpretation. Discrepancies were resolved through discussion and consensus between the 2 coders; when consensus could not be reached, a third investigator reviewed the relevant responses and adjudicated the final coding decision. The final themes were refined through iterative discussion among the research team to ensure that they reflected the participants&#x2019; comments and were aligned with the study objectives. Institution-type comparisons were conducted using repeated ratings from the same expert panel and were not based on mutually exclusive expert subgroups. Coding and category development were conducted using spreadsheet-based data matrices.</p></sec><sec id="s2-6"><title>Ethical Considerations</title><p>The study was reviewed by the Institutional Review Board of Asan Medical Center and was determined to be exempt from review (exemption number 2024&#x2010;1033). The study was conducted in accordance with relevant ethical guidelines. Participation was voluntary, informed consent was obtained from all participants prior to their involvement, and any information that could directly identify individual participants or their affiliated institutions was removed from the analytic dataset. Participants received an honorarium equivalent to approximately US $200 for their participation. No images or supplementary materials include identifiable individual participants, patients, users, or institutions.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><sec id="s3-1"><title>Participants</title><p>A total of 24 experts participated in the expert panel evaluation, including 4 patient safety specialists, 6 medical informatics professionals, 9 hospital information system practitioners, and 5 human factors experts (<xref ref-type="table" rid="table2">Table 2</xref>). Their academic backgrounds included IT (n=8), medicine (n=7), pharmacy (n=5), industrial engineering (n=2), and nursing (n=2). All participants had at least 10 years of professional or research experience in their respective fields and were recruited through recommendations from relevant academic societies or professional associations.</p><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Characteristics of the expert panel (N=24).</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Characteristics</td><td align="left" valign="bottom">Values, n (%)</td></tr></thead><tbody><tr><td align="left" valign="bottom" colspan="2">Sex</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Male</td><td align="left" valign="top">14 (58.3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Female</td><td align="left" valign="top">10 (41.7)</td></tr><tr><td align="left" valign="top" colspan="2">Age (y)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>30&#x2010;39</td><td align="left" valign="top">2 (8.3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>40&#x2010;49</td><td align="left" valign="top">9 (37.5)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>50&#x2010;59</td><td align="left" valign="top">12 (50)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>60&#x2010;69</td><td align="left" valign="top">1 (4.2)</td></tr><tr><td align="left" valign="top" colspan="2">Professional specialty</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Hospital information system</td><td align="left" valign="top">9 (37.5)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Medical informatics</td><td align="left" valign="top">6 (25)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Human factors</td><td align="left" valign="top">5 (20.8)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Patient safety</td><td align="left" valign="top">4 (16.7)</td></tr><tr><td align="left" valign="top" colspan="2">Educational background</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>IT</td><td align="left" valign="top">8 (33.3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Medicine</td><td align="left" valign="top">7 (29.2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Pharmacy</td><td align="left" valign="top">5 (20.8)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Industrial engineering</td><td align="left" valign="top">2 (8.3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Nursing</td><td align="left" valign="top">2 (8.3)</td></tr></tbody></table></table-wrap></sec><sec id="s3-2"><title>Quantitative Findings</title><p>I-CVI values ranged from 0.476 to 1.000 across item-dimension-institution&#x2013;type combinations, with most combinations demonstrating acceptable to high content validity. Content validity was generally high for tertiary referral hospitals and general hospitals, whereas greater variability was observed for clinics. The mean I-CVI values for the 10 certification item domains ranged from 0.797 to 0.992 after averaging across evaluation dimensions and health care institution types (<xref ref-type="fig" rid="figure2">Figure 2</xref>). The overall S-CVI/Ave was 0.921, indicating strong content validity across the 10 certification items. The number of valid ratings ranged from 21 to 24 across item-dimension-institution&#x2013;type combinations. The complete item-dimension-institution type values for I-CVI, probability of chance agreement (Pc), and modified &#x03BA;* are provided in <xref ref-type="supplementary-material" rid="app2">Multimedia Appendix 2</xref>. No item-level mean I-CVI fell at or below the predefined threshold of 0.78. However, 2 items (A021: Barcode or Radio Frequency Identification [RFID] Medication Administration and A025: Antibiotic Prescription Management) showed comparatively lower mean I-CVI values than the other certification item domains.</p><fig position="float" id="figure2"><label>Figure 2.</label><caption><p>Item-level Content Validity Index (I-CVI) scores for the 10 electronic medical record use certification item domains. Bars represent item-level mean I-CVI values averaged across evaluation dimensions and health care institution types. The dashed horizontal line represents the S-CVI/Ave (0.921). The y-axis was scaled from 0.700 to 1.000, with the maximum set to 1.000, consistent with the possible upper bound of the Content Validity Index (CVI). APM: Antibiotic Prescription Management; BRMA: Barcode or RFID Medication Administration; CTRN: Critical Test Result Notification; DAH: Drug Allergy and Hypersensitivity; DIA: Drug Interaction and Allergy Alert; IRAM: Inappropriate Route of Administration Management; MEP: Medication Entry Error Prevention; MIP: Medication Information Provision; PI: Patient Identification; RFID: radio frequency identification; S-CVI/Ave: scale-level Content Validity Index; SPMD: Safe Prescription of Medication Dosages.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="medinform_v14i1e95500_fig02.png"/></fig><p>The average I-CVI score was highest for relevance (mean 0.942, SD 0.105), followed by clarity (mean 0.925, SD 0.095), importance (mean 0.925, SD 0.091), and usefulness (mean 0.894, SD 0.142), indicating relatively lower expert agreement regarding practical utility.</p><p>Modified &#x03BA;* coefficients were computed for each combination of item, dimension, and institution type (tertiary referral hospitals, general hospitals, and clinics). Modified &#x03BA;* coefficients were generally consistent with I-CVI estimates for high-agreement combinations, whereas larger differences were observed for several lower-scoring clinic-level combinations.</p></sec><sec id="s3-3"><title>Content Validity by Health Care Institution Type</title><p>Content validity differed by health care institution types. The mean I-CVI values were 0.974 (SD 0.032) for tertiary referral hospitals, 0.963 (SD 0.051) for general hospitals, and 0.827 (SD 0.140) for clinics. Clinics showed lower average I-CVI values than those of tertiary referral hospitals and general hospitals, with mean I-CVI values of 0.838 (SD 0.110) for clarity and 0.757 (SD 0.172) for usefulness (<xref ref-type="fig" rid="figure3">Figure 3</xref>). At the clinic level, several item-dimension combinations did not meet the predefined acceptability threshold of I-CVI&#x2265;0.78 [<xref ref-type="bibr" rid="ref36">36</xref>]. Five of the 10 certification item domains had at least one clinic-level dimension below the threshold. A017 (Drug Interaction and Allergy Alert), A019 (Inappropriate Route of Administration Management), and A024 (Critical Test Result Notification) had below-threshold clinic-level usefulness scores of 0.762, 0.714, and 0.762, respectively. In addition, A021 (Barcode or RFID Medication Administration) scored below the threshold across all 4 dimensions: 0.667 for relevance, 0.476 for usefulness, 0.619 for clarity, and 0.667 for importance. A025 (Antibiotic Prescription Management) also scored below the threshold across all 4 dimensions: 0.524 for relevance, 0.476 for usefulness, 0.667 for clarity, and 0.667 for importance. These results show that clinic-level applicability concerns were most pronounced for A021 (Barcode or RFID Medication Administration) and A025 (Antibiotic Prescription Management), while usefulness concerns also extended to A017 (Drug Interaction and Allergy Alert), A019 (Inappropriate Route of Administration Management), and A024 (Critical Test Result Notification).</p><fig position="float" id="figure3"><label>Figure 3.</label><caption><p>Item-level Content Validity Index (I-CVI) scores by health care institution type across 4 content validity dimensions: relevance, usefulness, clarity, and importance.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="medinform_v14i1e95500_fig03.png"/></fig><p>Regarding &#x03BA;* coefficients, values for tertiary referral hospitals ranged from 0.917 to 1.000 across item-dimension combinations. &#x03BA;* values ranged from 0.809 to 1.000 for general hospitals and from 0.370 to 1.000 for clinics. Across tertiary referral hospitals, general hospitals, and clinics, &#x03BA;* values exceeded 0.900 for most item-dimension combinations across the 4 evaluation dimensions. The lowest modified &#x03BA; values were observed for clinic-level A021 usefulness and A025 usefulness, both of which had a modified &#x03BA; of 0.370. The probability of chance agreement ranged from approximately 0 to 0.168.</p></sec><sec id="s3-4"><title>Practical Feature Evaluation by Survey</title><p>In the expert-assessed practical feature evaluation, differences were observed across health care institution types. For target respondent suitability, the mean scores were 3.29 (SD 0.52) for tertiary referral hospitals, 3.04 (SD 0.52) for general hospitals, and 2.35 (SD 0.92) for clinics. For content adequacy, the corresponding scores were 2.75 (SD 0.56), 2.71 (SD 0.51), and 2.70 (SD 0.49). For ease of completion, the scores were 3.67 (SD 0.41), 3.44 (SD 0.57), and 2.92 (SD 0.91), respectively (<xref ref-type="table" rid="table3">Table 3</xref>).</p><table-wrap id="t3" position="float"><label>Table 3.</label><caption><p>Mean (SD) scores of practical features across health care institution types.</p></caption><table id="table3" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Item and type of health care institution</td><td align="left" valign="bottom">Value, mean (SD)</td></tr></thead><tbody><tr><td align="left" valign="top" colspan="2">Target respondent suitability</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Tertiary referral hospital</td><td align="left" valign="top">3.29 (0.52)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>General hospital</td><td align="left" valign="top">3.04 (0.52)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Clinic</td><td align="left" valign="top">2.35 (0.92)</td></tr><tr><td align="left" valign="top" colspan="2">Content adequacy</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Tertiary referral hospital</td><td align="left" valign="top">2.75 (0.56)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>General hospital</td><td align="left" valign="top">2.71 (0.51)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Clinic</td><td align="left" valign="top">2.70 (0.49)</td></tr><tr><td align="left" valign="top" colspan="2">Ease of completion</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Tertiary referral hospital</td><td align="left" valign="top">3.67 (0.41)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>General hospital</td><td align="left" valign="top">3.44 (0.57)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Clinic</td><td align="left" valign="top">2.92 (0.91)</td></tr></tbody></table></table-wrap></sec><sec id="s3-5"><title>Qualitative Findings</title><p>The thematic content analysis of open-ended expert feedback yielded 3 major themes: self-assessment as a preparatory mechanism for on-site evaluation, the conditional feasibility of self-assessment without on-site evaluation, and the need to distinguish between use certification and product certification. The results below summarize expert feedback corresponding to each theme.</p><sec id="s3-5-1"><title>Theme 1: Self-Assessment as a Preparatory Tool Prior to On-Site Evaluations</title><p>Most experts (n=16) expressed positive views regarding the potential utility of the self-assessment as a preparatory tool prior to on-site evaluations. They noted that, when used in this context, the checklist could serve as a valuable resource for preassessment. However, several limitations were identified. Specifically, concerns were raised about the usability of the self-assessment in smaller health care settings, particularly at clinics (eg, doctors&#x2019; offices). Experts suggested that separate self-assessments be developed for tertiary, secondary, and clinic-level institutions. Additionally, although the self-assessment is well-structured and easy to read, some content, particularly around medication safety, is repetitive and needs refinement. The clarification of vague terms, alignment with actual processes, and inclusion of implementation examples (eg, system screenshots or formats) were noted as potential considerations.</p><p>Experts emphasized that the pre&#x2013;self-assessment should primarily serve as a tool to verify whether the EMR format is appropriate, whether it is being maintained and improved to support patient care and safety, and to confirm the presence of the necessary organizational infrastructure to sustain its use.</p></sec><sec id="s3-5-2"><title>Theme 2: Conditional Feasibility of Self-Assessment Without On-Site Evaluation</title><p>Most experts (n=13) agreed that independent evaluations can be sufficiently used as an assessment tool, regardless of whether on-site evaluations are conducted. Self-assessments effectively verify compliance but have limited ability to drive necessary improvements for certification. They can complement but not replace on-site evaluations, which are essential owing to variations in question interpretation and response accuracy. Assessments conducted solely by clinicians (eg, physicians or nurses) are challenging, thereby emphasizing the need for clearer guidance and precise questions.</p><p>Experts identified several conditions that could enhance the feasibility of self-assessment, including clear identification of responsible personnel, explicit definitions within the evaluation criteria, and predefined thresholds for determining when follow-up on-site evaluation may be needed. Additionally, specifying department roles and encouraging detailed item-level participation were perceived as potentially enhancing efficiency. Including guidelines for question comprehension, requiring evidence submission (eg, screenshots), and verifying actual clinical use beyond the existence of a program were also identified as important considerations. For clinics without formal departmental structures, experts perceived that assigning responsible individuals and obtaining leadership confirmation may be particularly important for implementing the self-assessment process.</p></sec><sec id="s3-5-3"><title>Theme 3: Need to Distinguish Use Certification From Product Certification</title><p>Several experts noted that the current self-checklist can be used for tertiary referral hospitals, but a separate use certification, distinct from product certification, may be unnecessary. Although improvements are possible, especially in assessing actual clinical use rather than just product features, the distinction between product and use certification remains unclear. Use certification should focus on verifying real-world applications, such as allergy registration and alert use, and incorporate data on actual system use rather than simply confirming feature availability. Additionally, evaluation criteria should be customized to reflect differences in workflows and medication management across different hospital types.</p><p>Although the evaluation forms are detailed, they can be difficult for smaller clinics and would benefit from simplification and clearer instructions. Providing additional support, such as clinic-specific guides, separate questionnaires for IT and clinical staff, and help desk services, would enhance the process. Experts suggested that evaluation teams may need to include both IT/system managers and clinical users to ensure that the assessment reflects both system functionality and clinical workflow. Additionally, focusing on usability, providing actionable feedback, and implementing effective scoring will improve adoption. Some assessment items may require adjustment to better reflect real-world conditions. Overall, the evaluation framework is solid but should be tailored to the institution&#x2019;s size and role to increase clarity, usability, and effectiveness.</p></sec></sec><sec id="s3-6"><title>Appraisee Composition</title><p>In the summary evaluation, experts estimated the minimum number of personnel or professional roles required to complete the 10 self-evaluation forms for each health care institution type. The estimated number was highest for tertiary referral hospitals (mean 3.42, SD 1.89), followed by general hospitals (mean 2.95, SD 1.10) and clinics (mean 2.20, SD 0.83). These values refer to expert-estimated minimum personnel requirements for checklist completion, not to actual study participants. However, responses also indicated that smaller medical institutions would be more difficult to evaluate, even when system administrators (IT personnel or related departments) and users (medical professionals) are involved, either alone or in collaboration.</p></sec><sec id="s3-7"><title>Expert Feedback on Certification Items Across Health Care Institution Types</title><p>First, experts expressed that tertiary care facilities need precise, standardized processes and advanced functionalities to ensure patient safety and clinical accuracy. Critical areas include rigorous patient identification protocols, allergy and drug interaction checks, and prevention of medication entry errors with a focus on look-alike/sound-alike drugs. Robust management of administration routes and integration of weight data for dose calculation are important but are challenged by workload and data accuracy. Barcode and RFID medication administration systems were recognized as key patient safety tools, but experts noted that their implementation requires substantial investment and institutional commitment. Antibiotic stewardship systems should prioritize alerts for restricted drugs, with flexible approval workflows acknowledging physician shortages. Although medication information provision and critical test-result notifications are valued, costs and clarity in guideline definitions remain concerns. Overall, tertiary referral hospitals require scalable, comprehensive solutions that balance safety, workflow efficiency, and resource constraints.</p><p>For general hospitals, experts noted challenges related to specialist availability and resource constraints. They require simplified, well-integrated tools that prioritize practical management over technical complexity. Patient identification and allergy documentation systems should ensure consistency but remain adaptable to fewer staff. Medication error prevention and administration route management need structured but feasible processes supported by pharmacy departments that may face staffing challenges. Barcode and RFID implementations are rare and often cost-prohibitive, necessitating external support and tailored investment plans. Antibiotic management must consider the absence of infectious disease specialists and focus on institution-specific restrictions. Medication information provision and test result notifications, although important, must be balanced against limited financial and operational capacity.</p><p>For clinics, experts noted that limited staffing and simpler prescribing workflows require highly practical and cost-effective solutions. Patient identification and allergy alert systems should be straightforward and easy to use, prioritizing usability over complexity. Medication entry error prevention and dose calculation features have limited utility because of the infrequent use of complex or high-risk drugs. Barcode and RFID systems are generally impractical due to cost, low drug complexity, and limited administration procedures. Antibiotic stewardship in clinics should focus on education and awareness, with flexible, low-burden monitoring rather than strict electronic controls. Medication information provision is largely the responsibility of pharmacies, and critical test-result notifications are rare and limited to basic omission checks. Overall, experts noted that clinic-level EMR use certification involves balancing safety features with simplicity, cost-efficiency, and workflow practicality.</p></sec><sec id="s3-8"><title>Integration of Quantitative and Qualitative Findings</title><p>To integrate the quantitative and qualitative strands, we developed a joint display that links expert feedback with corresponding quantitative results and mixed methods interpretations of checklist validity and feasibility (<xref ref-type="table" rid="table4">Table 4</xref>).</p><table-wrap id="t4" position="float"><label>Table 4.</label><caption><p>Joint display integrating qualitative feedback and quantitative results on checklist validity and feasibility.</p></caption><table id="table4" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Qualitative explanation from expert feedback</td><td align="left" valign="bottom">Quantitative results</td><td align="left" valign="bottom">Integrated mixed methods interpretation</td></tr></thead><tbody><tr><td align="left" valign="top">Cost burden, limited staffing, and infrequent medication administration procedures were identified as barriers to A021<sup><xref ref-type="table-fn" rid="table4fn1">a</xref></sup> implementation in clinics.</td><td align="left" valign="top">A021 clinic I-CVI<sup><xref ref-type="table-fn" rid="table4fn2">b</xref></sup> was below the threshold across all dimensions: relevance, 0.667; usefulness, 0.476; clarity, 0.619; importance, 0.667.</td><td align="left" valign="top">A021 may require clinic-specific adaptation because low ratings aligned with implementation and workflow constraints.</td></tr><tr><td align="left" valign="top">Limited infectious disease specialist support and need for low-burden approaches were identified as barriers to A025<sup><xref ref-type="table-fn" rid="table4fn3">c</xref></sup> implementation in clinics.</td><td align="left" valign="top">A025 clinic I-CVI was below the threshold across all dimensions: relevance, 0.524; usefulness, 0.476; clarity, 0.667; importance, 0.667.</td><td align="left" valign="top">A025 may require lower-burden implementation models for clinics with limited specialist capacity.</td></tr><tr><td align="left" valign="top">Several items were described as clinically important but difficult to operationalize in smaller institutions.</td><td align="left" valign="top">&#x201C;Usefulness&#x201D; was the lowest-rated dimension: overall, 0.894; clinic-level, 0.757.</td><td align="left" valign="top">Experts distinguished clinical importance from practical implementability, particularly in clinics.</td></tr><tr><td align="left" valign="top">Documentation burden, evidence submission, and respondent identification were identified as barriers to completion.</td><td align="left" valign="top">&#x201C;Ease of completion&#x201D; was lower in clinics: 2.92 (SD 0.91) vs 3.67 (SD 0.41) in tertiary referral hospitals and 3.44 (SD 0.57) in general hospitals.</td><td align="left" valign="top">Completion burden was more pronounced in clinics than in larger institutions.</td></tr></tbody></table><table-wrap-foot><fn id="table4fn1"><p><sup>a</sup>A021 refers to the Barcode or RFID Medication Administration item.</p></fn><fn id="table4fn2"><p><sup>b</sup>I-CVI: item-level Content Validity Index.</p></fn><fn id="table4fn3"><p><sup>c</sup>A025 refers to the Antibiotic Prescription Management item.</p></fn></table-wrap-foot></table-wrap></sec></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><sec id="s4-1"><title>Principal Findings</title><p>This study identified high overall content validity for the proposed self-assessment checklist for EMR use, while also showing variation in expert-assessed usefulness and feasibility across health care institution types, particularly in clinical settings.</p></sec><sec id="s4-2"><title>Interpretation and Implications</title><p>The expert panel&#x2019;s evaluation demonstrated high overall content validity, with an S-CVI/Ave of 0.921. This finding suggests that the selected KHIS-designated certification items were generally perceived as relevant, important, clear, and useful for evaluating patient safety-critical aspects of EMR use. Across the 4 evaluation dimensions, relevance showed the highest agreement, whereas usefulness was relatively lower, indicating that experts distinguished the clinical importance of the items from their feasibility in routine implementation.</p><p>The lower clinic-level ratings were not limited to A021 (Barcode or RFID Medication Administration) and A025 (Antibiotic Prescription Management). Although these 2 items fell below the predefined I-CVI threshold across all 4 evaluation dimensions, clinic-level usefulness scores were also below the threshold for A017 (Drug Interaction and Allergy Alert), A019 (Inappropriate Route of Administration Management), and A024 (Critical Test Result Notification). This pattern suggests that clinic-level concerns were concentrated not only in resource-intensive medication administration and antibiotic stewardship functions but also in the perceived usefulness of selected decision-support and notification functions. These findings strengthen the need for tiered, capacity-sensitive implementation guidance rather than a uniform certification approach across all health care institution types. Qualitative feedback suggested that these lower ratings may reflect concerns related to implementation cost, staffing, workflow structure, and limited specialist support. For example, these findings are consistent with qualitative feedback, indicating that medication safety functions may be viewed as clinically important but difficult to operationalize in smaller institutions.</p><p>The institution-type differences observed in this study support the need for context-sensitive interpretation of EMR use certification items. Tertiary referral hospitals and general hospitals showed higher average I-CVI values than clinics, whereas clinic-level ratings indicated lower perceived applicability and practical usefulness for selected functions and greater difficulty in identifying appropriate respondents or responsible personnel. These findings do not necessarily indicate that the underlying patient safety objectives are less important in clinics. Rather, they suggest that workflow fit, implementation requirements, organizational responsibility, and availability of resources may differ across institution types. These patterns suggest that a uniform self-assessment approach may not adequately reflect differences in organizational capacity, governance structures, and available technical support across health care settings.</p><p>These findings can be interpreted through sociotechnical perspectives on health IT safety, which emphasize that safety risks may emerge from interactions among technology, users, workflows, and organizational context rather than from software functionality alone [<xref ref-type="bibr" rid="ref8">8</xref>-<xref ref-type="bibr" rid="ref10">10</xref>,<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref30">30</xref>]. The checklist items examined in this study&#x2014;patient identification, medication safety, decision support, critical result communication, and antibiotic stewardship&#x2014;therefore represent patient safety-critical areas in which both technical functions and real-world use conditions require attention [<xref ref-type="bibr" rid="ref39">39</xref>-<xref ref-type="bibr" rid="ref43">43</xref>].</p><p>Medication safety-related items accounted for several of the lower-rated certification items and item-level evaluations, highlighting the importance of context-sensitive interpretation. Closed-loop medication management, barcode or RFID-based medication administration, clinical decision support alerts, and critical result notification are widely recognized as important safety functions, but their effectiveness depends on workflow fit, alert configuration, documentation practices, escalation protocols, and organizational accountability [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref40">40</xref>,<xref ref-type="bibr" rid="ref41">41</xref>,<xref ref-type="bibr" rid="ref44">44</xref>]. Expert feedback in this study similarly indicated that these functions may be clinically important but difficult to implement uniformly across health care institution types, particularly in clinics with limited staffing, specialist support, or medication administration workflows.</p><p>Organizational capacity emerged as a critical determinant of expert-assessed feasibility. One possible explanation is that general hospitals and clinics may have fewer dedicated IT personnel, less formalized governance structures, and more limited capacity for continuous EMR optimization than tertiary referral hospitals. The consistently lower clinic-level ratings, particularly for identifying appropriate respondents or responsible personnel, may reflect these structural constraints rather than a lack of recognition of patient safety priorities.</p><p>These findings support a tiered and context-sensitive approach to EMR use certification. A consistent set of patient safety objectives may be retained across institution types, but implementation guidance, evidence requirements, and support mechanisms may need to differ according to institutional readiness. For general hospitals and clinics, targeted support such as vendor participation, standardized implementation guidance, and financial incentives may be needed before use certification can be applied in a feasible and equitable manner.</p><p>The self-assessment checklist developed in this study should be positioned as a foundational component of EMR use certification rather than as a stand-alone substitute for all forms of use evaluations. The checklist provides a structured mechanism for documenting implementation status, governance, and improvement needs for patient safety-critical EMR functions. Scenario-based evaluations or direct workflow observations can complement the checklist by verifying how selected high-risk functions operate in real clinical contexts. Thus, the checklist can serve as a preparatory and screening tool that informs more targeted scenario-based evaluations.</p></sec><sec id="s4-3"><title>Strengths and Limitations</title><p>This study offers important insights into the development and content validation of a self-assessment checklist aligned with the Korean EMR Certification System; however, several limitations should be noted. First, the validation process primarily relied on the CVI. Although the CVI is a widely accepted method in instrument development and is supplemented by qualitative feedback from open-ended questions, it remains inherently subjective, as it is based on expert judgments. Although the modified &#x03BA; was calculated to adjust each I-CVI for the probability of chance agreement, the modified &#x03BA; is a chance-adjusted content-validity coefficient rather than a comprehensive measure of interrater reliability. Conventional interrater reliability metrics were not evaluated; therefore, expert agreement beyond the CVI-based acceptability assessment and chance-adjusted content-validity assessment could not be fully characterized. This approach may not fully capture the complexity of how the checklist performs in diverse, real-world health care settings. In addition, the number of valid ratings varied across item-dimension-institution&#x2013;type combinations owing to missing ratings. Although missing ratings were excluded only from the specific calculations in which they occurred, differential nonresponse by institution type may have influenced some estimates, particularly for general hospital and clinic-level evaluations.</p><p>Second, the panel of experts, although experienced in health information systems and EMR certification, may not adequately represent the full spectrum of stakeholders involved in EMR implementation. Important perspectives from frontline clinical staff, EMR vendors, health care administrators, patient advocates, and policymakers were limited or absent, which may have influenced feedback regarding the checklist&#x2019;s clarity, applicability, and usability. The expert panel was also unevenly distributed across stakeholder groups and health care institution types and was selected primarily on the basis of expertise in EMR certification and health information systems rather than representation across health care institution types. Some experts were not affiliated with health care institutions, and among those with health care institution affiliations, participants were concentrated in large tertiary or university-affiliated hospitals. Although the expert panel included a physician currently practicing in a primary care clinic, frontline representation from clinical settings remained limited. Accordingly, clinic-level findings should be interpreted cautiously as expert-assessed applicability rather than definitive evidence from a broad sample of frontline primary care clinicians or clinic managers.</p><p>Third, the study design required experts to provide numerous quantitative ratings across multiple dimensions and settings, as well as practical assessments and open-ended feedback. This may have imposed a high cognitive burden and contributed to survey fatigue, particularly influencing responses related to ease of completion.</p><p>Fourth, the validation was limited to content validity. Other important psychometric properties, such as construct validity, criterion-related validity, and reliability, were not evaluated. These aspects are essential for establishing the robustness, consistency, and generalizability of the checklist, especially if it is intended for use in formal evaluations or regulatory settings.</p><p>Finally, although the adaptation of the ONC checklist to the Korean context was carried out using a structured approach, it may not have fully captured certain localized clinical practices or regulatory nuances. Continuous refinement through pilot testing and real-world application in Korean health care settings is essential to ensure the checklist&#x2019;s relevance and alignment with actual certification processes and clinical workflows.</p><p>Future research should empirically test the checklist across diverse health care environments, evaluate additional dimensions of validity and reliability, and examine how checklist use relates to implementation processes and patient safety-relevant outcomes. It will also be important to incorporate feedback from a broader range of end users, including frontline clinicians, administrators, EMR vendors, clinic managers, policymakers, and patients. These efforts may help determine whether the tool is practical, reliable, and useful for supporting EMR certification and patient safety&#x2013;focused evaluation in routine clinical settings.</p></sec><sec id="s4-4"><title>Conclusions</title><p>This study developed and evaluated the content validity of a self-assessment checklist for EMR use certification focused on 10 patient safety&#x2013;related certification items aligned with the Korean EMR Certification System. Expert evaluation demonstrated high overall content validity, supporting the relevance and appropriateness of the selected domains for assessing EMR use in clinical practice. However, perceived applicability and expert-assessed feasibility varied across tertiary referral hospitals, general hospitals, and clinics, suggesting that institutional context should be considered when applying the checklist. These results support the checklist as a foundational self-assessment tool for evaluating patient safety-critical aspects of EMR use. Further empirical testing is needed to examine its reliability, feasibility, and utility in real-world certification processes.</p></sec></sec></body><back><notes><sec><title>Generative AI Use</title><p>The authors declare limited use of ChatGPT (OpenAI), a generative AI (GenAI) tool, during manuscript preparation. In accordance with the Generative AI Disclosure Tool (GAIDeT) taxonomy (2025), GenAI tools were used solely to assist with translation under full human supervision. Following AI-assisted translation, the manuscript underwent professional English-language editing by a third-party service to ensure clarity, accuracy, and consistency of language. All AI-generated outputs and editorial suggestions were reviewed and approved by the authors. Responsibility for the scientific content, interpretation, and final manuscript rests entirely with the authors. GenAI tools are not listed as authors and do not bear responsibility for the final outcomes.</p></sec><sec><title>Funding</title><p>This study was funded by a grant from the Korea Health Technology R&#x0026;D Project through the Korea Health Industry Development Institute, funded by the Ministry of Health and Welfare, Republic of Korea (grant number RS-2025&#x2010;02213061). The funder had no role in study design, data collection, data analysis or interpretation, or manuscript writing.</p></sec><sec><title>Data Availability</title><p>The datasets generated and analyzed during the current study are not publicly available owing to a lack of prior consideration for data sharing during study design and institutional review board approval. However, the data are available from the corresponding author upon reasonable request and with approval from the Asan Medical Center Institutional Data Access/Ethics Committee (contact: irb@amc.seoul.kr or +82-2-3010-7166).</p></sec></notes><fn-group><fn fn-type="con"><p>Conceptualization: JC, YL</p><p>Data curation: YEP</p><p>Formal analysis: JC, YEP</p><p>Funding acquisition: YL</p><p>Investigation: YEP, YL</p><p>Methodology: YL</p><p>Project administration: YL</p><p>Resources: JC, YK</p><p>Supervision: YL</p><p>Validation: JC, JHL, YL</p><p>Visualization: YL, YEP</p><p>Writing &#x2013; original draft: JC, YEP</p><p>Writing &#x2013; review and editing: YL, YEP</p><p>All authors read and approved the final manuscript.</p></fn><fn fn-type="conflict"><p>YK was affiliated with the Korea Health Information Service (KHIS), which developed the certification items evaluated in this study. To minimize potential bias and support analytic independence, qualitative coding and discrepancy adjudication were conducted by investigators who were not affiliated with the KHIS. The KHIS-affiliated author provided contextual input regarding the certification system but did not participate in qualitative coding, adjudication, or calculation of the Content Validity Index results. The other authors declare no conflicts of interest.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">CVI</term><def><p>Content Validity Index</p></def></def-item><def-item><term id="abb2">EHR</term><def><p>electronic health record</p></def></def-item><def-item><term id="abb3">EMR</term><def><p>electronic medical record</p></def></def-item><def-item><term id="abb4">I-CVI</term><def><p>item-level Content Validity Index</p></def></def-item><def-item><term id="abb5">KHIS</term><def><p>Korea Health Information Service</p></def></def-item><def-item><term id="abb6">ONC</term><def><p>US Office of the National Coordinator for Health Information Technology</p></def></def-item><def-item><term id="abb7">RFID</term><def><p>radio frequency identification</p></def></def-item><def-item><term id="abb8">S-CVI/Ave</term><def><p>scale-level Content Validity Index</p></def></def-item><def-item><term id="abb9">WHO</term><def><p>World Health Organization</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="report"><article-title>Global strategy on digital health 2020&#x2013;2025</article-title><year>2021</year><access-date>2026-10-15</access-date><publisher-name>World Health Organization</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://www.who.int/docs/default-source/documents/gs4dhdaa2a9f352b0445bafbc79ca799dce4d.pdf">https://www.who.int/docs/default-source/documents/gs4dhdaa2a9f352b0445bafbc79ca799dce4d.pdf</ext-link></comment></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="report"><person-group person-group-type="author"><name name-style="western"><surname>Baek</surname><given-names>J</given-names> </name><name name-style="western"><surname>Kang</surname><given-names>H</given-names> </name><name name-style="western"><surname>Oh</surname><given-names>S</given-names> </name><name name-style="western"><surname>Kang</surname><given-names>S</given-names> </name></person-group><article-title>A comparative study of five countries on expanding electronic medical record (EMR) certification system: focusing on supports for small hospitals [Report in Korean]</article-title><year>2022</year><access-date>2026-10-20</access-date><publisher-name>Korea Institute for Health and Social Affairs (KIHASA)</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://repository.kihasa.re.kr/bitstream/201002/40945/8/%EC%9B%8C%ED%82%B9%ED%8E%98%EC%9D%B4%ED%8D%BC%202022-02.pdf">https://repository.kihasa.re.kr/bitstream/201002/40945/8/%EC%9B%8C%ED%82%B9%ED%8E%98%EC%9D%B4%ED%8D%BC%202022-02.pdf</ext-link></comment></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Greggio</surname><given-names>J</given-names> </name><name name-style="western"><surname>Stogiannos</surname><given-names>N</given-names> </name><name name-style="western"><surname>Stewart</surname><given-names>KL</given-names> </name><etal/></person-group><article-title>Exploring digital twinning in MRI: a systematic review of current applications, barriers, and future opportunities</article-title><source>Radiography (Lond)</source><year>2026</year><month>05</month><volume>32</volume><issue>4</issue><fpage>103413</fpage><pub-id pub-id-type="doi">10.1016/j.radi.2026.103413</pub-id><pub-id pub-id-type="medline">41996784</pub-id></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chimbo</surname><given-names>B</given-names> </name><name name-style="western"><surname>Motsi</surname><given-names>L</given-names> </name></person-group><article-title>The effects of electronic health records on medical error reduction: extension of the DeLone and McLean information system success model</article-title><source>JMIR Med Inform</source><year>2024</year><month>10</month><day>16</day><volume>12</volume><fpage>e54572</fpage><pub-id pub-id-type="doi">10.2196/54572</pub-id><pub-id pub-id-type="medline">39412857</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chrimes</surname><given-names>D</given-names> </name><name name-style="western"><surname>Thomo</surname><given-names>A</given-names> </name><name name-style="western"><surname>Kuo</surname><given-names>MHA</given-names> </name><name name-style="western"><surname>Borycki</surname><given-names>EM</given-names> </name><name name-style="western"><surname>Kushniruk</surname><given-names>A</given-names> </name></person-group><article-title>Predicting electronic health record usability: scoping review of adoption models, metrics, and future directions</article-title><source>JMIR Hum Factors</source><year>2026</year><month>04</month><day>8</day><volume>13</volume><fpage>e86076</fpage><pub-id pub-id-type="doi">10.2196/86076</pub-id><pub-id pub-id-type="medline">41950355</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Alqahtani</surname><given-names>FSA</given-names> </name><name name-style="western"><surname>Belal</surname><given-names>AA</given-names> </name><name name-style="western"><surname>Zakri</surname><given-names>NI</given-names> </name></person-group><article-title>Impact of governance, risk management and compliance on healthcare system: a systematic review</article-title><source>J Contemp Dent Pract</source><year>2025</year><month>09</month><day>1</day><volume>26</volume><issue>9</issue><fpage>904</fpage><lpage>911</lpage><pub-id pub-id-type="doi">10.5005/jp-journals-10024-3943</pub-id><pub-id pub-id-type="medline">41316978</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="report"><article-title>ONC health IT certification program overview</article-title><year>2022</year><access-date>2026-10-07</access-date><publisher-name>Office of the National Coordinator for Health Information Technology (ONC), U.S. Department of Health and Human Services (HHS)</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://healthit.gov/certification-health-it/about-onc-health-it-certification-program/">https://healthit.gov/certification-health-it/about-onc-health-it-certification-program/</ext-link></comment></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Carayon</surname><given-names>P</given-names> </name><name name-style="western"><surname>Wetterneck</surname><given-names>TB</given-names> </name><name name-style="western"><surname>Rivera-Rodriguez</surname><given-names>AJ</given-names> </name><etal/></person-group><article-title>Human factors systems approach to healthcare quality and patient safety</article-title><source>Appl Ergon</source><year>2014</year><month>01</month><volume>45</volume><issue>1</issue><fpage>14</fpage><lpage>25</lpage><pub-id pub-id-type="doi">10.1016/j.apergo.2013.04.023</pub-id><pub-id pub-id-type="medline">23845724</pub-id></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sittig</surname><given-names>DF</given-names> </name><name name-style="western"><surname>Singh</surname><given-names>H</given-names> </name></person-group><article-title>A new sociotechnical model for studying health information technology in complex adaptive healthcare systems</article-title><source>Qual Saf Health Care</source><year>2010</year><month>10</month><volume>19 Suppl 3</volume><issue>Suppl 3</issue><fpage>i68</fpage><lpage>74</lpage><pub-id pub-id-type="doi">10.1136/qshc.2010.042085</pub-id><pub-id pub-id-type="medline">20959322</pub-id></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sittig</surname><given-names>DF</given-names> </name><name name-style="western"><surname>Singh</surname><given-names>H</given-names> </name></person-group><article-title>Electronic health records and national patient-safety goals</article-title><source>N Engl J Med</source><year>2012</year><month>11</month><day>8</day><volume>367</volume><issue>19</issue><fpage>1854</fpage><lpage>1860</lpage><pub-id pub-id-type="doi">10.1056/NEJMsb1205420</pub-id><pub-id pub-id-type="medline">23134389</pub-id></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cahill</surname><given-names>M</given-names> </name><name name-style="western"><surname>Cleary</surname><given-names>BJ</given-names> </name><name name-style="western"><surname>Cullinan</surname><given-names>S</given-names> </name></person-group><article-title>The influence of electronic health record design on usability and medication safety: systematic review</article-title><source>BMC Health Serv Res</source><year>2025</year><month>01</month><day>6</day><volume>25</volume><issue>1</issue><fpage>31</fpage><pub-id pub-id-type="doi">10.1186/s12913-024-12060-2</pub-id><pub-id pub-id-type="medline">39762805</pub-id></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Fang</surname><given-names>Q</given-names> </name><name name-style="western"><surname>Liang</surname><given-names>J</given-names> </name><name name-style="western"><surname>Xiang</surname><given-names>P</given-names> </name><etal/></person-group><article-title>Electronic health record downtime events of a hospital: a retrospective analysis from adverse event reports</article-title><source>Appl Clin Inform</source><year>2025</year><month>10</month><volume>16</volume><issue>5</issue><fpage>1419</fpage><lpage>1429</lpage><pub-id pub-id-type="doi">10.1055/a-2701-5819</pub-id><pub-id pub-id-type="medline">41135583</pub-id></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Li</surname><given-names>E</given-names> </name><name name-style="western"><surname>Clarke</surname><given-names>J</given-names> </name><name name-style="western"><surname>Ashrafian</surname><given-names>H</given-names> </name><name name-style="western"><surname>Darzi</surname><given-names>A</given-names> </name><name name-style="western"><surname>Neves</surname><given-names>AL</given-names> </name></person-group><article-title>The impact of electronic health record interoperability on safety and quality of care in high-income countries: systematic review</article-title><source>J Med Internet Res</source><year>2022</year><month>09</month><day>15</day><volume>24</volume><issue>9</issue><fpage>e38144</fpage><pub-id pub-id-type="doi">10.2196/38144</pub-id><pub-id pub-id-type="medline">36107486</pub-id></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Murthi</surname><given-names>S</given-names> </name><name name-style="western"><surname>Martini</surname><given-names>N</given-names> </name><name name-style="western"><surname>Falconer</surname><given-names>N</given-names> </name><name name-style="western"><surname>Scahill</surname><given-names>S</given-names> </name></person-group><article-title>Evaluating EHR-integrated digital technologies for medication-related outcomes and health equity in hospitalised adults: a scoping review</article-title><source>J Med Syst</source><year>2024</year><month>08</month><day>23</day><volume>48</volume><issue>1</issue><fpage>79</fpage><pub-id pub-id-type="doi">10.1007/s10916-024-02097-5</pub-id><pub-id pub-id-type="medline">39174723</pub-id></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Spaar</surname><given-names>P</given-names> </name><name name-style="western"><surname>Krevat</surname><given-names>SM</given-names> </name><name name-style="western"><surname>Boxley</surname><given-names>CL</given-names> </name><name name-style="western"><surname>Mohan</surname><given-names>V</given-names> </name><name name-style="western"><surname>Ratwani</surname><given-names>RM</given-names> </name><name name-style="western"><surname>Gold</surname><given-names>JA</given-names> </name></person-group><article-title>Analysis of patient safety event report to understand the contribution of health IT to diagnostic error</article-title><source>J Patient Saf</source><year>2026</year><month>03</month><day>1</day><volume>22</volume><issue>2</issue><fpage>162</fpage><lpage>167</lpage><pub-id pub-id-type="doi">10.1097/PTS.0000000000001434</pub-id><pub-id pub-id-type="medline">41215574</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="web"><article-title>Electronic Medical Record Adoption Model (EMRAM)&#x00AE;</article-title><source>HIMSS (Healthcare Information and Management Systems Society)</source><access-date>2025-07-08</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.himss.org/maturity-models/emram/">https://www.himss.org/maturity-models/emram/</ext-link></comment></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="web"><article-title>EMR system certification</article-title><source>KHIS (Korea Health Information Service)</source><access-date>2025-08-04</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://k-his.or.kr/menu.es?mid=a20201010100">https://k-his.or.kr/menu.es?mid=a20201010100</ext-link></comment></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Harrison</surname><given-names>MI</given-names> </name><name name-style="western"><surname>Koppel</surname><given-names>R</given-names> </name><name name-style="western"><surname>Bar-Lev</surname><given-names>S</given-names> </name></person-group><article-title>Unintended consequences of information technologies in health care&#x2014;an interactive sociotechnical analysis</article-title><source>J Am Med Inform Assoc</source><year>2007</year><volume>14</volume><issue>5</issue><fpage>542</fpage><lpage>549</lpage><pub-id pub-id-type="doi">10.1197/jamia.M2384</pub-id><pub-id pub-id-type="medline">17600093</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Howe</surname><given-names>JL</given-names> </name><name name-style="western"><surname>Adams</surname><given-names>KT</given-names> </name><name name-style="western"><surname>Hettinger</surname><given-names>AZ</given-names> </name><name name-style="western"><surname>Ratwani</surname><given-names>RM</given-names> </name></person-group><article-title>Electronic health record usability issues and potential contribution to patient harm</article-title><source>JAMA</source><year>2018</year><month>03</month><day>27</day><volume>319</volume><issue>12</issue><fpage>1276</fpage><lpage>1278</lpage><pub-id pub-id-type="doi">10.1001/jama.2018.1171</pub-id><pub-id pub-id-type="medline">29584833</pub-id></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Friedman</surname><given-names>CP</given-names> </name><name name-style="western"><surname>Wong</surname><given-names>AK</given-names> </name><name name-style="western"><surname>Blumenthal</surname><given-names>D</given-names> </name></person-group><article-title>Achieving a nationwide learning health system</article-title><source>Sci Transl Med</source><year>2010</year><month>11</month><day>10</day><volume>2</volume><issue>57</issue><fpage>57cm29</fpage><pub-id pub-id-type="doi">10.1126/scitranslmed.3001456</pub-id><pub-id pub-id-type="medline">21068440</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lee</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Bahn</surname><given-names>S</given-names> </name><name name-style="western"><surname>Shin</surname><given-names>GW</given-names> </name><etal/></person-group><article-title>Development of safety and usability guideline for clinical information system</article-title><source>Medicine (Baltimore)</source><year>2021</year><month>04</month><day>2</day><volume>100</volume><issue>13</issue><fpage>e25276</fpage><pub-id pub-id-type="doi">10.1097/MD.0000000000025276</pub-id><pub-id pub-id-type="medline">33787612</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Shin</surname><given-names>GW</given-names> </name><name name-style="western"><surname>Lee</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Park</surname><given-names>T</given-names> </name><etal/></person-group><article-title>Investigation of usability problems of electronic medical record systems in the emergency department</article-title><source>Work</source><year>2022</year><volume>72</volume><issue>1</issue><fpage>221</fpage><lpage>238</lpage><pub-id pub-id-type="doi">10.3233/WOR-205262</pub-id><pub-id pub-id-type="medline">34120924</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lee</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Jung</surname><given-names>MY</given-names> </name><name name-style="western"><surname>Shin</surname><given-names>GW</given-names> </name><etal/></person-group><article-title>Safety and usability guidelines of clinical information systems integrating clinical workflow: a systematic review</article-title><source>Healthc Inform Res</source><year>2018</year><month>07</month><volume>24</volume><issue>3</issue><fpage>157</fpage><lpage>169</lpage><pub-id pub-id-type="doi">10.4258/hir.2018.24.3.157</pub-id><pub-id pub-id-type="medline">30109149</pub-id></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lee</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Shin</surname><given-names>SY</given-names> </name><name name-style="western"><surname>Kim</surname><given-names>JY</given-names> </name><etal/></person-group><article-title>Evaluation of mobile health applications developed by a tertiary hospital as a tool for quality improvement breakthrough</article-title><source>Healthc Inform Res</source><year>2015</year><month>10</month><volume>21</volume><issue>4</issue><fpage>299</fpage><lpage>306</lpage><pub-id pub-id-type="doi">10.4258/hir.2015.21.4.299</pub-id><pub-id pub-id-type="medline">26618037</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kim</surname><given-names>YG</given-names> </name><name name-style="western"><surname>Jung</surname><given-names>K</given-names> </name><name name-style="western"><surname>Park</surname><given-names>YT</given-names> </name><etal/></person-group><article-title>Rate of electronic health record adoption in South Korea: a nation-wide survey</article-title><source>Int J Med Inform</source><year>2017</year><month>05</month><volume>101</volume><fpage>100</fpage><lpage>107</lpage><pub-id pub-id-type="doi">10.1016/j.ijmedinf.2017.02.009</pub-id><pub-id pub-id-type="medline">28347440</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Yoon</surname><given-names>D</given-names> </name><name name-style="western"><surname>Chang</surname><given-names>BC</given-names> </name><name name-style="western"><surname>Kang</surname><given-names>SW</given-names> </name><name name-style="western"><surname>Bae</surname><given-names>H</given-names> </name><name name-style="western"><surname>Park</surname><given-names>RW</given-names> </name></person-group><article-title>Adoption of electronic health records in Korean tertiary teaching and general hospitals</article-title><source>Int J Med Inform</source><year>2012</year><month>03</month><volume>81</volume><issue>3</issue><fpage>196</fpage><lpage>203</lpage><pub-id pub-id-type="doi">10.1016/j.ijmedinf.2011.12.002</pub-id><pub-id pub-id-type="medline">22206619</pub-id></nlm-citation></ref><ref id="ref27"><label>27</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Park</surname><given-names>RW</given-names> </name><name name-style="western"><surname>Shin</surname><given-names>SS</given-names> </name><name name-style="western"><surname>Choi</surname><given-names>YI</given-names> </name><name name-style="western"><surname>Ahn</surname><given-names>JO</given-names> </name><name name-style="western"><surname>Hwang</surname><given-names>SC</given-names> </name></person-group><article-title>Computerized physician order entry and electronic medical record systems in Korean teaching and general hospitals: results of a 2004 survey</article-title><source>J Am Med Inform Assoc</source><year>2005</year><volume>12</volume><issue>6</issue><fpage>642</fpage><lpage>647</lpage><pub-id pub-id-type="doi">10.1197/jamia.M1768</pub-id><pub-id pub-id-type="medline">16049229</pub-id></nlm-citation></ref><ref id="ref28"><label>28</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tookman</surname><given-names>L</given-names> </name><name name-style="western"><surname>Lear</surname><given-names>R</given-names> </name><name name-style="western"><surname>Abdullahi</surname><given-names>YS</given-names> </name><etal/></person-group><article-title>Understanding and addressing challenges with electronic health record use in gynecological oncology: cross-sectional survey of multidisciplinary professionals in the United Kingdom and co-design of an integrated informatics platform to support clinical decision-making</article-title><source>JMIR Cancer</source><year>2025</year><month>09</month><day>10</day><volume>11</volume><fpage>e58657</fpage><pub-id pub-id-type="doi">10.2196/58657</pub-id><pub-id pub-id-type="medline">40929723</pub-id></nlm-citation></ref><ref id="ref29"><label>29</label><nlm-citation citation-type="web"><article-title>Real world testing</article-title><source>ONC (Office of the National Coordinator for Health Information Technology)</source><access-date>2025-07-10</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.healthit.gov/topic/certification-ehrs/real-world-testing">https://www.healthit.gov/topic/certification-ehrs/real-world-testing</ext-link></comment></nlm-citation></ref><ref id="ref30"><label>30</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cresswell</surname><given-names>K</given-names> </name><name name-style="western"><surname>Sheikh</surname><given-names>A</given-names> </name></person-group><article-title>Organizational issues in the implementation and adoption of health information technology innovations: an interpretative review</article-title><source>Int J Med Inform</source><year>2013</year><month>05</month><volume>82</volume><issue>5</issue><fpage>e73</fpage><lpage>86</lpage><pub-id pub-id-type="doi">10.1016/j.ijmedinf.2012.10.007</pub-id><pub-id pub-id-type="medline">23146626</pub-id></nlm-citation></ref><ref id="ref31"><label>31</label><nlm-citation citation-type="web"><source>Canada Health Infoway&#x2014;Acceler&#x014D;</source><access-date>2025-08-09</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://accelero.infoway-inforoute.ca/en">https://accelero.infoway-inforoute.ca/en</ext-link></comment></nlm-citation></ref><ref id="ref32"><label>32</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lim</surname><given-names>M</given-names> </name><name name-style="western"><surname>An</surname><given-names>D</given-names> </name><name name-style="western"><surname>Son</surname><given-names>N</given-names> </name><name name-style="western"><surname>Sunwoo</surname><given-names>W</given-names> </name><name name-style="western"><surname>Lee</surname><given-names>S</given-names> </name></person-group><article-title>A practical approach to assessing the completeness of electronic health records for medical research: data quality study</article-title><source>JMIR Med Inform</source><year>2026</year><month>05</month><day>21</day><volume>14</volume><fpage>e68935</fpage><pub-id pub-id-type="doi">10.2196/68935</pub-id><pub-id pub-id-type="medline">42166766</pub-id></nlm-citation></ref><ref id="ref33"><label>33</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Zhang</surname><given-names>T</given-names> </name><name name-style="western"><surname>Shin</surname><given-names>N</given-names> </name></person-group><article-title>From interface to outcome: a 4I framework for AI-linked functionality in electronic health records</article-title><source>BMC Med Inform Decis Mak</source><year>2026</year><month>05</month><day>22</day><volume>26</volume><issue>1</issue><fpage>268</fpage><pub-id pub-id-type="doi">10.1186/s12911-026-03562-6</pub-id><pub-id pub-id-type="medline">42174575</pub-id></nlm-citation></ref><ref id="ref34"><label>34</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Meeks</surname><given-names>DW</given-names> </name><name name-style="western"><surname>Takian</surname><given-names>A</given-names> </name><name name-style="western"><surname>Sittig</surname><given-names>DF</given-names> </name><name name-style="western"><surname>Singh</surname><given-names>H</given-names> </name><name name-style="western"><surname>Barber</surname><given-names>N</given-names> </name></person-group><article-title>Exploring the sociotechnical intersection of patient safety and electronic health record implementation</article-title><source>J Am Med Inform Assoc</source><year>2014</year><month>02</month><volume>21</volume><issue>e1</issue><fpage>e28</fpage><lpage>34</lpage><pub-id pub-id-type="doi">10.1136/amiajnl-2013-001762</pub-id><pub-id pub-id-type="medline">24052536</pub-id></nlm-citation></ref><ref id="ref35"><label>35</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lynn</surname><given-names>MR</given-names> </name></person-group><article-title>Determination and quantification of content validity</article-title><source>Nurs Res</source><year>1986</year><volume>35</volume><issue>6</issue><fpage>382</fpage><lpage>385</lpage><pub-id pub-id-type="medline">3640358</pub-id></nlm-citation></ref><ref id="ref36"><label>36</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Polit</surname><given-names>DF</given-names> </name><name name-style="western"><surname>Beck</surname><given-names>CT</given-names> </name></person-group><article-title>The content validity index: are you sure you know what&#x2019;s being reported? Critique and recommendations</article-title><source>Res Nurs Health</source><year>2006</year><month>10</month><volume>29</volume><issue>5</issue><fpage>489</fpage><lpage>497</lpage><pub-id pub-id-type="doi">10.1002/nur.20147</pub-id><pub-id pub-id-type="medline">16977646</pub-id></nlm-citation></ref><ref id="ref37"><label>37</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Polit</surname><given-names>DF</given-names> </name><name name-style="western"><surname>Beck</surname><given-names>CT</given-names> </name><name name-style="western"><surname>Owen</surname><given-names>SV</given-names> </name></person-group><article-title>Is the CVI an acceptable indicator of content validity? Appraisal and recommendations</article-title><source>Res Nurs Health</source><year>2007</year><month>08</month><volume>30</volume><issue>4</issue><fpage>459</fpage><lpage>467</lpage><pub-id pub-id-type="doi">10.1002/nur.20199</pub-id><pub-id pub-id-type="medline">17654487</pub-id></nlm-citation></ref><ref id="ref38"><label>38</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Wynd</surname><given-names>CA</given-names> </name><name name-style="western"><surname>Schmidt</surname><given-names>B</given-names> </name><name name-style="western"><surname>Schaefer</surname><given-names>MA</given-names> </name></person-group><article-title>Two quantitative approaches for estimating content validity</article-title><source>West J Nurs Res</source><year>2003</year><month>08</month><volume>25</volume><issue>5</issue><fpage>508</fpage><lpage>518</lpage><pub-id pub-id-type="doi">10.1177/0193945903252998</pub-id><pub-id pub-id-type="medline">12955968</pub-id></nlm-citation></ref><ref id="ref39"><label>39</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Adams</surname><given-names>KT</given-names> </name><name name-style="western"><surname>Pruitt</surname><given-names>Z</given-names> </name><name name-style="western"><surname>Kazi</surname><given-names>S</given-names> </name><etal/></person-group><article-title>Identifying health information technology usability issues contributing to medication errors across medication process stages</article-title><source>J Patient Saf</source><year>2021</year><month>12</month><day>1</day><volume>17</volume><issue>8</issue><fpage>e988</fpage><lpage>e994</lpage><pub-id pub-id-type="doi">10.1097/PTS.0000000000000868</pub-id><pub-id pub-id-type="medline">34009868</pub-id></nlm-citation></ref><ref id="ref40"><label>40</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lacson</surname><given-names>R</given-names> </name><name name-style="western"><surname>O&#x2019;Connor</surname><given-names>SD</given-names> </name><name name-style="western"><surname>Andriole</surname><given-names>KP</given-names> </name><name name-style="western"><surname>Prevedello</surname><given-names>LM</given-names> </name><name name-style="western"><surname>Khorasani</surname><given-names>R</given-names> </name></person-group><article-title>Automated critical test result notification system: architecture, design, and assessment of provider satisfaction</article-title><source>AJR Am J Roentgenol</source><year>2014</year><month>11</month><volume>203</volume><issue>5</issue><fpage>W491</fpage><lpage>6</lpage><pub-id pub-id-type="doi">10.2214/AJR.14.13063</pub-id><pub-id pub-id-type="medline">25341163</pub-id></nlm-citation></ref><ref id="ref41"><label>41</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lacson</surname><given-names>R</given-names> </name><name name-style="western"><surname>O&#x2019;Connor</surname><given-names>SD</given-names> </name><name name-style="western"><surname>Sahni</surname><given-names>VA</given-names> </name><etal/></person-group><article-title>Impact of an electronic alert notification system embedded in radiologists&#x2019; workflow on closed-loop communication of critical results: a time series analysis</article-title><source>BMJ Qual Saf</source><year>2016</year><month>07</month><volume>25</volume><issue>7</issue><fpage>518</fpage><lpage>524</lpage><pub-id pub-id-type="doi">10.1136/bmjqs-2015-004276</pub-id><pub-id pub-id-type="medline">26374896</pub-id></nlm-citation></ref><ref id="ref42"><label>42</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Palojoki</surname><given-names>S</given-names> </name><name name-style="western"><surname>Saranto</surname><given-names>K</given-names> </name><name name-style="western"><surname>Reponen</surname><given-names>E</given-names> </name><name name-style="western"><surname>Skants</surname><given-names>N</given-names> </name><name name-style="western"><surname>Vakkuri</surname><given-names>A</given-names> </name><name name-style="western"><surname>Vuokko</surname><given-names>R</given-names> </name></person-group><article-title>Classification of electronic health record&#x2013;related patient safety incidents: development and validation study</article-title><source>JMIR Med Inform</source><year>2021</year><month>08</month><day>31</day><volume>9</volume><issue>8</issue><fpage>e30470</fpage><pub-id pub-id-type="doi">10.2196/30470</pub-id><pub-id pub-id-type="medline">34245558</pub-id></nlm-citation></ref><ref id="ref43"><label>43</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Roumeliotis</surname><given-names>N</given-names> </name><name name-style="western"><surname>Sniderman</surname><given-names>J</given-names> </name><name name-style="western"><surname>Adams-Webber</surname><given-names>T</given-names> </name><etal/></person-group><article-title>Effect of electronic prescribing strategies on medication error and harm in hospital: a systematic review and meta-analysis</article-title><source>J Gen Intern Med</source><year>2019</year><month>10</month><volume>34</volume><issue>10</issue><fpage>2210</fpage><lpage>2223</lpage><pub-id pub-id-type="doi">10.1007/s11606-019-05236-8</pub-id><pub-id pub-id-type="medline">31396810</pub-id></nlm-citation></ref><ref id="ref44"><label>44</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Gani</surname><given-names>I</given-names> </name><name name-style="western"><surname>Litchfield</surname><given-names>I</given-names> </name><name name-style="western"><surname>Shukla</surname><given-names>D</given-names> </name><name name-style="western"><surname>Delanerolle</surname><given-names>G</given-names> </name><name name-style="western"><surname>Cockburn</surname><given-names>N</given-names> </name><name name-style="western"><surname>Pathmanathan</surname><given-names>A</given-names> </name></person-group><article-title>Understanding &#x201C;alert fatigue&#x201D; in primary care: qualitative systematic review of general practitioners&#x2019; attitudes and experiences of clinical alerts, prompts, and reminders</article-title><source>J Med Internet Res</source><year>2025</year><month>02</month><day>7</day><volume>27</volume><fpage>e62763</fpage><pub-id pub-id-type="doi">10.2196/62763</pub-id><pub-id pub-id-type="medline">39918864</pub-id></nlm-citation></ref></ref-list><app-group><supplementary-material id="app1"><label>Multimedia Appendix 1</label><p>Self-assessment checklist for evaluating electronic medical record use certification items.</p><media xlink:href="medinform_v14i1e95500_app1.pdf" xlink:title="PDF File, 677 KB"/></supplementary-material><supplementary-material id="app2"><label>Multimedia Appendix 2</label><p>Complete item-level Content Validity Index, probability of chance agreement, and modified &#x03BA; values by item, dimension, and health care institution type.</p><media xlink:href="medinform_v14i1e95500_app2.pdf" xlink:title="PDF File, 195 KB"/></supplementary-material></app-group></back></article>