This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Informatics, is properly cited. The complete bibliographic information, a link to the original publication on http://medinform.jmir.org/, as well as this copyright and license information must be included.
Moving to electronic health records (EHRs) confers substantial benefits but risks unintended consequences. Modern EHRs consist of complex software code with extensive local configurability options, which can introduce defects. Defects in clinical decision support (CDS) tools are surprisingly common. Feasible approaches to prevent and detect defects in EHR configuration, including CDS tools, are needed. In complex software systems, use of test–driven development and automated regression testing promotes reliability. Test–driven development encourages modular, testable design and expanding regression test coverage. Automated regression test suites improve software quality, providing a “safety net” for future software modifications. Each automated acceptance test serves multiple purposes, as requirements (prior to build), acceptance testing (on completion of build), regression testing (once live), and “living” design documentation. Rapid-cycle development or “agile” methods are being successfully applied to CDS development. The agile practice of automated test–driven development is not widely adopted, perhaps because most EHR software code is vendor-developed. However, key CDS advisory configuration design decisions and rules stored in the EHR may prove amenable to automated testing as “executable requirements.”
We aimed to establish feasibility of acceptance test–driven development of clinical decision support advisories in a commonly used EHR, using an open source automated acceptance testing framework (FitNesse).
Acceptance tests were initially constructed as spreadsheet tables to facilitate clinical review. Each table specified one aspect of the CDS advisory’s expected behavior. Table contents were then imported into a test suite in FitNesse, which queried the EHR database to automate testing. Tests and corresponding CDS configuration were migrated together from the development environment to production, with tests becoming part of the production regression test suite.
We used test–driven development to construct a new CDS tool advising Emergency Department nurses to perform a swallowing assessment prior to administering oral medication to a patient with suspected stroke. Test tables specified desired behavior for (1) applicable clinical settings, (2) triggering action, (3) rule logic, (4) user interface, and (5) system actions in response to user input. Automated test suite results for the “executable requirements” are shown prior to building the CDS alert, during build, and after successful build.
Automated acceptance test–driven development and continuous regression testing of CDS configuration in a commercial EHR proves feasible with open source software. Automated test–driven development offers one potential contribution to achieving high-reliability EHR configuration. Vetting acceptance tests with clinicians elicits their input on crucial configuration details early during initial CDS design and iteratively during rapid-cycle optimization.
“Making the right thing the easy thing to do” for clinicians using an electronic health record (EHR) drives many current efforts to promote delivery of reliable, high-quality care. Clinical decision support (CDS) within the EHR provides one mechanism, by supplying advisories suggesting best practice care for a patient’s specific conditions [
With the move to EHRs came recognition that unintended consequences can ensue [
Defects in CDS tools are surprisingly common and can cause either over-expression or under-expression of alerts [
In complex software systems, use of test–driven development (TDD) and automated regression testing promotes reliability [
Benefits of TDD include (1) encouragement of modular design and (2) growth of regression test suites. Automated regression test suites improve software quality and provide a “safety net” for later modification without fear of undetected breakage [
Rapid-cycle development or “agile” methods are being successfully applied to CDS development [
any
the
Test–driven development cycle.
In this paper, we use examples of each of the above (in a widely used EHR) to demonstrate how TDD of CDS advisories can work in practice during development of a CDS tool.
Patients who present to the emergency room with an acute stroke may have impaired swallowing mechanisms. Attempting to give medications orally creates a risk of the patient aspirating medication into the lungs. Accordingly, patients with known or suspected stroke are screened for swallowing difficulties prior to attempting administration of oral medication. In a busy emergency room setting, keeping track of whether the needed screening has been done can be challenging. Accordingly, interruptive CDS was requested if the intended swallow screening had not yet occurred.
All activities in this report took place at the University of Texas Southwestern Medical Center in Dallas, Texas. This work was judged not to be human subjects research and thus did not require presentation to our Institutional Review Board.
Automated testing employed the open source testing software FitNesse, based on the Framework for Integrated Testing, along with the dbFit extension for querying databases [
Initial high-level requirements for new CDS advisories were gathered as user stories [
Through clinical conversations, user stories were elaborated with more specific acceptance criteria describing what would constitute successful CDS advisory behavior, often initially as a simple bulleted list. In this project, certain acceptance criteria were further detailed unambiguously as automatable acceptance tests.
Acceptance tests were initially constructed as tables in a spreadsheet (Microsoft Excel workbook), to facilitate clinical vetting and shared review. Each table specified one configuration aspect of the CDS advisory. Table contents were then imported into an automated test suite in FitNesse (see the earlier section, Software). For each table-based test, a structured query language (SQL) query retrieved the corresponding CDS advisory configuration information from the EHR development environment’s database. A FitNesse test suite template was created containing the most frequently used specification tables and corresponding SQL queries, streamlining test generation for each new CDS advisory.
For configuration management, both the CDS advisory and its associated test were migrated from the development environment to the test environment at the same time, for integrated testing. Similarly, when migrating to production, the corresponding FitNesse test(s) were added to the automated regression test suite for the production environment.
Configuration of FitNesse and dbFit: time and personnel requirements. EHR: electronic health record; IT: information technology; SQL: structured query language.
Task category | Task | Frequency | Time (range) | Type of personnel |
Initial set-up of FitNesse + dbFit testing framework | Download and install FitNesse to point of functioning FitNesse wiki | Once | 30 minutes | IT analyst |
Configure FitNesse to use Active Directory login permissions (if desired) | Once | 2 hours to 1 day | IT analyst knowledgeable about one’s local Active Directory | |
Configure dbFit | Once | Few minutes to 2 hours | IT analyst | |
Set up database connection for FitNesse/dbFit to query an EHR (or other) database | Once per database | 1 hour (if first time doing); a few minutes per connection once experienced | IT analyst | |
Create a test “template” for a given type of test | Write SQL to serve as template for given type of test | Once per new type of test | 1 to 2 hours | EHR analyst; SQL writer (can be same person) |
Configure an individual test instance | Create Microsoft Excel copy of test template and populate for given test instance, ready for vetting with clinician or other customer | Once per test instance | 15 to 60 minutes | EHR analyst |
Import Microsoft Excel test to FitNesse Test page, and test | Once per test instance | 10 to 15 minutes | EHR analyst or test team analyst |
Any subsequent failures of regression tests in production would initiate a new entry in the incident management system for investigation and resolution.
A nurse informaticist (EF) and an EHR analyst (JO) met with the front-line nurses and nurse manager from the Emergency Department (ED) to define the problem and frame the user story for the alert in a way these nurse clinicians believed would be beneficial within their workflow. The same EHR analyst also had standing meetings with the ED nursing and medical staff at least weekly; those sessions were used to further elaborate more detailed acceptance criteria for the user story.
“As an emergency room nurse, I want to be alerted before I administer an oral medication to a patient with known or suspected stroke if they’ve not yet had their Swallow Screen performed, so that my patient can receive their medications by the most safe and effective route.”
Restrictions help focus the advisory to the right practice setting and clinician type, reducing alert fatigue for clinicians where the advisory would not be relevant (
Triggering actions further focus when the advisory’s logic should be evaluated to the most relevant point(s) in clinicians’ workflow—for example, only when entering or signing an order, entering a diagnosis, administering a medication, or (most invasively) on every entry into the patient’s chart. Our stroke swallowing advisory was to trigger logic evaluation when the nurse prepares a medication for administration to a patient—specifically, at the time of barcode scanning the medication due (
The rule logic for deciding whether a CDS advisory should appear to a clinician was first modeled as a decision tree (
In addition to specifying the wording on the advisory (not shown and which includes instructional diagrams and text for performing the Swallow Screen), acceptance tests can also specify what follow-up actions the clinician may be prompted to perform (
This requirement test specified that the nurse should be able to indicate directly from the alert’s UI whether the patient passed or failed the Swallow Screen, without having to leave the alert and navigate to the swallow screening flowsheet in another part of the chart. This follow-up action still populated the same flowsheet behind the scenes, however, for data consistency. Neither option was to be defaulted as pre-selected—both were specified to initially appear unselected.
As an alternative to the prompted action, the clinician may select an “acknowledge reason” exception why the primary action was not taken, resulting in the system setting a “lock out” time to avoid repetitive firing, and optionally file a specific data element for data capture (
For instance, Line 1 of this test specifies that once a clinician determines oral medications are allowed for this patient, the alert should not fire on subsequent medication administrations during the current ED encounter for a lockout period of 24 hours, limiting alert fatigue.
Screenshot of FitNesse test specifying Department Specialty and Provider Type restrictions. n/a: not applicable.
Screenshot of test specifying triggering action for this advisory.
Decision tree for the advisory. NIH: National Institutes of Health.
Screenshot of test specifying clinical decision support rule logic. CINN: Cincinnati; NIH: National Institutes of Health.
Screenshot of test specifying user interface actions for the advisory. BPA: Best Practice Advisory
Screenshot of test specifying system actions following clinician response. BPA: Best Practice Advisory; PO: per os.
Before development has begun, all test assertions should fail and do (
During development, some tests begin to pass. When construction of the CDS advisory is complete, the test suite can indicate if any requirements are not yet met (
FitNesse automatically displays any discrepancies between expected and actual advisory design. On Line 1 in
Following completion of build and resolution of any discrepancies from specified requirements, the test page for the “base” alert record passes completely (
Similar test pages were developed to specify acceptance criteria for the 5 “criteria” records referenced by the base alert record (see
For reference, our current FitNesse regression test suite in production currently has 85 Test Pages, 6126 individual test Assertions, and runs in 165 seconds (2 min, 45 sec). Once the automated acceptance tests are fully passing, the CDS advisory then can be migrated from the Development environment to the Integrated Testing environment, and then to Production. The automated acceptance test suite is also added to the regression test suites in the latter two environments contemporaneously with migrating the CDS code, to ensure continued proper behavior in all environments.
Screenshot of acceptance test: all assertions fail as expected prior to build.
Screenshot of a test table included in the acceptance test suite: acceptance test partially passes following initial build. GCS: Glasgow Coma Scale; PO: per os.
Screenshot of acceptance test assertions for "base" alert record, all passing following successful build. BPA: Best Practice Advisory; PO: per os.
Test suite: number of tests and individual assertions, with execution times. NIH: National Institutes of Health.
Type | Test page name | Tests | Assertions | Time (s) |
Base | Alert Stroke Suspected But No Swallow Screen | 8 | 48 | 0.003 |
Criteria | Criteria Abnormal Cincinnati Stroke Scale | 3 | 14 | 0.002 |
Criteria | Criteria NIH Stroke Scale Ordered | 3 | 19 | 0.001 |
Criteria | Criteria Code Stroke Ordered | 4 | 24 | 0.002 |
Criteria | Criteria Med With Oral Route | 3 | 19 | 0.002 |
Criteria | Criteria Stroke Dysphagia Screen Performed | 3 | 14 | 0.002 |
Suite | Suite Story Stroke Swallow Screen | 24 | 138 | 0.869 |
Three 2-week development iterations were required for full implementation of this advisory, following requirements gathering with a user story and initial acceptance criteria.
During a first 2-week iteration, automated acceptance tests were written and a first working version of the best practice advisory created and demonstrated. During testing, we discovered that the initial follow-up action specified by the test (a hyperlink to jump the nurse to the Swallow Screen documentation flowsheet) was not compatible with the trigger action desired (beginning medication administration).
Accordingly, during a follow-on 2-week iteration, we pivoted to a different follow-up action to be taken from the advisory’s UI, which enabled the nurse to document the Stroke Swallow screen results directly from the advisory UI. This filed the nurse’s response to the identical Stroke Swallow documentation flowsheet row, while avoiding the need for the nurse to leave the advisory and jump to the flowsheet itself. Since the advisory’s UI also includes graphical instructions for performing the Stroke Swallow screen, this approach was well received by nursing representatives.
During a third 2-week iteration, the alert was turned on in Production silently (not visible to end-users) to observe what situations triggered its firing. No over-firing in unwanted situations was detected. Under-firing was observed, due to frequent use in the ED of as-needed oral medication orders rather than scheduled medication orders. The criteria record’s rule determining whether oral meds were ordered originally used a property evaluating for oral scheduled medications. This rule was re-specified to include an additional property evaluating for as-needed oral medications as well. After development to pass the revised test, the modified rule was re-migrated to Production.
The alert was re-observed silently in Production for approximately 24 hours prior to enabling its display to end-users. Investigation of the alert’s criteria evaluation for both real ED patients and test patients confirmed that the alert was behaving as expected in Production. Following “go-live” of the visible alert, no customer-logged “tickets” for aberrant alert behavior (eg, firing in unintended locations or situations) were received.
Defects and unintended consequences occur too commonly in CDS advisories present in modern complex EHRs. Test–driven development offers one approach to help achieve higher reliability. In this study, we used open source software (FitNesse) to create “executable requirements” covering multiple important structural and behavioral dimensions of CDS advisory design: restrictions to applicable clinical settings, trigger(s) to invoke rule evaluation, rule logic, UI design, and system responses to clinician selections. This work demonstrates that acceptance TDD can feasibly be applied to configuring CDS advisories in a commercial EHR, generating suites of automated acceptance and regression tests.
User-centered design methods now being applied in health care seek to optimize clinician and patient experience with software and include the equivalent of iterative manual acceptance testing [
In this study, we demonstrated the feasibility of using TDD for CDS configuration in a commercial EHR: investigation over a longer period of adoption will be needed to measure the effect of TDD on CDS tools’ quality in production.
The example chosen shows application of TDD to only one type of CDS (best practice advisories), in an advisory executing simple logic. However, the FitNesse framework in our experience can be readily applied to specifying more complex CDS rule logic assessing a wide variety of patient-specific data in the EHR and to testing many other aspects of EHR and non-EHR system configuration. For instance, we have applied FitNesse automated testing to:
ensuring conformance with data business rules not enforced directly in software (eg, “If a provider is marked as participating in the EHR Incentive Program, they should also have their e-Prescribing flag set to Yes”)
specifying expected contents of tables with potential for major downstream impact if unexpectedly changed (eg, exact contents of the Provider Type and Encounter Type look-up tables, used extensively in CDS targeting, in reporting, and in a variety of operational uses)
cross-system testing of mutually consistent configuration (eg, for the exact operating room location of vital sign monitoring equipment used by anesthesiologists, validate 100% consistency between middleware software and the EHR, to ensure vital signs are always interfaced to the correct surgical patient’s record)
Given this versatility, we expect automated acceptance TDD to prove readily applicable to other types of CDS (such as order sets, cascading order questions, and rule-driven banners).
Another potential limitation is that FitNesse by design tests software “under the hood”; that is, under the UI level. FitNesse purposefully tests the business logic and data storage layers driving important application behavior, ideally insulated by modular design from minor modifications to the UI. Automated testing through the UI generally requires more maintenance and is more time-consuming and expensive to configure [
Automated acceptance testing and continuous regression testing of CDS configuration in a commercial EHR proves feasible with open source software. The problem of EHR safety is multifaceted, and multiple safety-enhancing approaches will almost certainly be needed [
As another benefit, clinician frustration with the EHR can be reduced by judiciously limiting interruptive alerts to truly relevant circumstances where pop-up advice is seen as helpful, not extraneous [
FitNesse test tables for Stroke Swallow Advisory - main alert record.
FitNesse test tables for Stroke Swallow Advisory - criteria records.
Best Practice Advisory
clinical decision support
electronic health record
Glasgow Coma Scale
information technology
National Institutes of Health
per os
structured query language
test–driven development
We thank our colleagues in UT Southwestern’s Health System Information Resources and Enterprise Data Services departments for configuring the FitNesse automated testing framework, with a special thanks to Preston Park. We appreciate the leadership support of Marc Milstein, Mark Rauschuber, Kathryn Flores, Dennis Pfeifer, and Ki Lai making this work possible. Research was supported in part by NIH Grant: 5UL1TR001105-05 UT Southwestern Center for Translational Medicine.